China High Quality Clamp Type Current Transformer

  • Model NO.: Lzck-55
  • Type: Current Transformer
  • Operation Condition: Outdoor
  • Winding Form: Single Layer & Tightly Wound Type
  • Installation: Active Type
  • Voltage Transformation Principle: Electromagnetic Type
  • Rated Voltage: 35kv, 10kv
  • Rated Frequency: 50Hz or 60Hz
  • Types: Clamp Type Current Transformer
  • Working Temperature: -20-55 Deg
  • Fs: <10
  • Specification: CE, ISO9001: 2008, IEC
  • HS Code: 8504311000
  • Application: Electronic, Instrument, Position Sensor, Audio, Lighting
  • Phase: Single
  • Usage: Measurement
  • Insulating Medium: Epoxy Resin
  • Magnetic Circuit Structure: Single Stage Type
  • Model: Lzck-55
  • Rated Secondary Current: 5A or 1A
  • Accuracy: 0.5s/0.5/1
  • Ratio: 100-1500A/5A
  • Weight: 2kg
  • Trademark: GFUVE
  • Origin: Beijing, China
LZCK-55 OUTDOOR CT clamp type current transformer
LZCK series instrument current transformers applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV, and microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, have the characteristics of Small magnetic circuit loss and can be cut, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case which is flame retardance anti-moisture, stable performance, no maintenance.
Working conditions:
Ambient temperature: -35° C~+55° C, not exceeding +40° C.
The Height of above sea level: 0~ 3000m.
Atmosphere conditions: No highly polluted, errosion, erosiveness, radioactivity gases.
(continuous working under the rated current is allowed)
(P2 represents for primary polar end, S1, S2 represent for secondary polar end
P2 and S2 are subtractive polarity.
Technical parameters: :
Rated frequency: : 50Hz or 60Hz
Rated secondary current: 5A or 1A
Secondary winding power frequency withstand voltage: 3kV, 1min
Safety Factor Rating (FS) < 5
Standard of Application: GB1208-2006; IEC 60044-1; NTC 2205
Accuracy Class: 0.5S or 0.5, 1;
Item Name
Range of primary rated current
Range of Rated load
(mm)(Description)
(Weight)(kg)

Item Name
 

Range of primary rated current
 

Range of Rated load
 

(mm)(Description)
 

(Weight) ( kg )
 

LZCK110-10
 

300-600A
 

≤5VA
 

φ64×φ104×32
 

0.6
 

LZCK310-10
 

300-600A
 

≤5VA
 

φ50×φ110×32
 

0.6
 

LZCK322-10
 

30-600A
 

≤10VA
 

φ50×φ110×52
 

1.6
 

LZCK350-10
 

30-600A
 

≤25VA
 

φ50×φ110×105
 

3.1
 

LZCK020-10
 

300-600A
 

≤5VA
 

φ55×φ86×50
 

0.5
 

LZCK830-35
 

50-600A
 

≤10VA
 

φ66×φ130×70
 

2.0
 

EZ Check Scanner Cleaning Cards

Check Scanner can easily get dirty on the rollers, sensor and magnetic head contaminated by the ink on the check. It is critical to keep your check scanner clean to prevent read failure. Mediclean Check Reader Cleaning Card can come with IPA or Alcohol Free Solution made in USA. All sizes can be customized to compatible with different check scanner models. One card can be used for 6-8 times through different direction. Our Check Scanner Cleaning Cards can work with Epson, Digital Check, Burroughs, Canon check scanners. Mediclean also provide Check Scanner Cleaning Swab and Cleaning Wipes to thoroughly clean the rollers and sensor.

Check Scanner Cleaning Card

EZ Check Scanner Cleaning Cards

Check Scanner Cleaning Cards, Check Reader Cleaning Card, Digital Check Panini Cleaning Cards, Check Scanner Cleaning Swab, Canon Epson Cleaning Cards, Check Scanner Cleaning Wipes

Mediclean Technology Co.,LTD. , http://www.mediclean-tech.com